For directors, the rule added 20 CE hours on director responsibilities to most non-pathologist pathways, replaced 'physical science' degrees with chemical, biological, clinical or medical lab science and coursework alternatives, required on-site visits at least every 6 months (4 months apart) with documentation, and grandfathered anyone serving as a director on December 28, 2024.
Summary of director changes
| Area | Before | Now (42 CFR 493.1405 / 493.1443) |
|---|---|---|
| Degrees | Included physical science degrees | Chemical, biological, clinical or medical lab science or MT, or defined coursework/thesis equivalents |
| CE | Physician pathway could use 20 CME hours or residency training as an option | 20 CE hours covering director responsibilities required for most non-pathologist pathways |
| On-site presence | No specific frequency | At least every 6 months, 4 months apart, documented (§ 493.1407(c), § 493.1445(c)) |
| High complexity physicians | Residency training or experience options | 2 years directing or supervising high complexity testing + 20 CE hours |
| Grandfathering | - | Qualified and serving on Dec 28, 2024 and continuously since |
What directors should do now
- Confirm which pathway you qualify under and keep the evidence on file.
- Complete and file 20 CE hours if your pathway needs them.
- Set a visit calendar for each lab and record what you do on each visit.
- If grandfathered, keep proof of continuous service since December 28, 2024.
- Review technical consultant and supervisor qualifications; those changed too.
Other parts of the rule
The same rule updated CLIA fees and the qualifications for technical consultants, supervisors and testing personnel, and added a bachelor's-equivalency definition. Sound Lab Consultants can review your whole personnel roster against the current rules.
Regulations behind this page
Every requirement on this page comes from the CLIA regulations, Title 42 Code of Federal Regulations Part 493. Open any section for the official text.
| Regulation | What it covers |
|---|---|
| 42 CFR § 493.1405Standard; Laboratory director qualifications | Moderate complexity laboratory director qualifications |
| 42 CFR § 493.1407Standard; Laboratory director responsibilities | Moderate complexity laboratory director responsibilities |
| 42 CFR § 493.1443Standard; Laboratory director qualifications | High complexity laboratory director qualifications |
| 42 CFR § 493.1445Standard; Laboratory director responsibilities | High complexity laboratory director responsibilities |
Full text: 42 CFR § 493.1405 Standard; Laboratory director qualifications
§ 493.1405 Standard; Laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and the performance of moderate complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R of this part. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must— (1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology; or (2)(i) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (ii) Have had laboratory training or experience consisting of: (A) At least 1 year directing or supervising nonwaived laboratory testing; and (B) Have at least 20 CE credit hours in laboratory practice that cover the laboratory director responsibilities defined in § 493.1407; or (3)(i)(A) Hold an earned doctoral degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) Hold an earned doctoral degree; and ( 1 ) Have at least 16 semester hours of doctoral level coursework in biology, chemistry, medical technology (MT), clinical laboratory science (CLS), or medical laboratory science (MLS); or ( 2 ) An approved thesis or research project in biology/chemistry/MT/CLS/MLS related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Have at least 20 CE credit hours in laboratory practice that cover the laboratory director responsibilities defined in § 493.1407; and (A) Be certified and continue to be certified by a board approved by HHS; and (B) Have had at least 1 year of experience directing or supervising nonwaived laboratory testing; or (4)(i)(A) Have earned a master's degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B)( 1 ) Meet bachelor's degree equivalency; and (2) Have at least 16 semester hours of additional graduate level coursework in biology, chemistry, medical technology, clinical or medical laboratory science; or (C)( 1 ) Meet bachelor's degree equivalency; and ( 2 ) Have at least 16 semester hours in a combination of graduate level coursework in biology, chemistry, medical technology, clinical or medical laboratory science and an approved thesis or research project related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Have at least 1 year of laboratory training or experience, or both, in nonwaived testing; and (iii) Have at least 1 year of supervisory laboratory experience in nonwaived testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1407; or (5)(i)(A) Have earned a bachelor's degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) At least 120 semester hours, or equivalent, from an accredited institution that, at a minimum, includes either— ( 1 ) Forty-eight (48) semester hours of medical laboratory science or medical laboratory technology courses; or ( 2 ) Forty-eight (48) semester hours of science courses that include— ( i ) Twelve (12) semester hours of chemistry, which must include general chemistry and biochemistry or organic chemistry; ( ii ) Twelve (12) semester hours of biology, which must include general biology and molecular biology, cell biology or genetics; and ( iii ) Twenty-four (24) semester hours of chemistry, biology, or medical laboratory science or medical laboratory technology in any combination; and (ii) Have at least 2 years of laboratory training or experience, or both, in nonwaived testing; and (iii) Have at least 2 years of supervisory laboratory experience in nonwaived testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1407. (6) Notwithstanding any other provision of this section, an individual is considered qualified as a laboratory director of moderate complexity testing under this section if they were qualified and serving as a laboratory director of moderate complexity testing in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. [57 FR 7172, Feb. 28, 1992, as amended at 58 FR 5233, Jan. 19, 1993; 88 FR 90039, Dec. 28, 2023]
Source: eCFR, Title 42, Part 493, current as of November 24, 2026.
Full text: 42 CFR § 493.1407 Standard; Laboratory director responsibilities
§ 493.1407 Standard; Laboratory director responsibilities. The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (a) The laboratory director, if qualified, may perform the duties of the technical consultant, clinical consultant, and testing personnel, or delegate these responsibilities to personnel meeting the qualifications of §§ 493.1409, 493.1415, and 493.1421, respectively. (b) If the laboratory director reapportions performance of his or her responsibilities, he or she remains responsible for ensuring that all duties are properly performed. (c) The laboratory director must: (1) Be onsite at least once every 6 months, with at least 4 months between the minimum two on-site visits. Laboratory directors may elect to be on-site more frequently and must continue to be accessible to the laboratory to provide telephone or electronic consultation as needed; and (2) Provide documentation of these visits, including evidence of performing activities that are part of the laboratory director responsibilities. (d) Each individual may direct no more than five laboratories. (e) The laboratory director must— (1) Ensure that testing systems developed and used for each of the tests performed in the laboratory provide quality laboratory services for all aspects of test performance, which includes the preanalytic, analytic, and postanalytic phases of testing; (2) Ensure that the physical plant and environmental conditions of the laboratory are appropriate for the testing performed and provide a safe environment in which employees are protected from physical, chemical, and biological hazards; (3) Ensure that— (i) The test methodologies selected have the capability of providing the quality of results required for patient care; (ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; and (iii) Laboratory personnel are performing the test methods as required for accurate and reliable results; (4) Ensure that the laboratory is enrolled in an HHS approved proficiency testing program for the testing performed and that— (i) The proficiency testing samples are tested as required under subpart H of this part; (ii) The results are returned within the timeframes established by the proficiency testing program; (iii) All proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require corrective action; and (iv) An approved corrective action plan is followed when any proficiency testing results are found to be unacceptable or unsatisfactory; (5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur; (6) Ensure the establishment and maintenance of acceptable levels of analytical performance for each test system; (7) Ensure that all necessary remedial actions are taken and documented whenever significant deviations from the laboratory's established performance specifications are identified, and that patient test results are reported only when the system is functioning properly; (8) Ensure that reports of test results include pertinent information required for interpretation; (9) Ensure that consultation is available to the laboratory's clients on matters relating to the quality of the test results reported and their interpretation concerning specific patient conditions; (10) Employ a sufficient number of laboratory personnel with the appropriate education and either experience or training to provide appropriate consultation, properly supervise and accurately perform tests and report test results in accordance with the personnel responsibilities described in this subpart; (11) Ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results; (12) Ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills; (13) Ensure that an approved procedure manual is available to all personnel responsible for any aspect of the testing process; and (14) Specify, in writing, the responsibilities and duties of each consultant and each person, engaged in the performance of the preanalytic, analytic, and postanalytic phases of testing, that identifies which examinations and procedures each individual is authorized to perform, whether supervision is required for specimen processing, test performance or results reporting, and whether consultant or director review is required prior to reporting patient test results. [57 FR 7172, Feb. 28, 1992, as amended at 68 FR 3713, Jan. 24, 2003; 88 FR 90039, Dec. 28, 2023]
Source: eCFR, Title 42, Part 493, current as of November 24, 2026.
Full text: 42 CFR § 493.1443 Standard; Laboratory director qualifications
§ 493.1443 Standard; Laboratory director qualifications. The laboratory director must be qualified to manage and direct the laboratory personnel and performance of high complexity tests and must be eligible to be an operator of a laboratory within the requirements of subpart R. (a) The laboratory director must possess a current license as a laboratory director issued by the State in which the laboratory is located, if such licensing is required; and (b) The laboratory director must— (1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology; or (2)(i) Be a doctor of medicine, a doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (ii) Have at least 2 years of experience directing or supervising high complexity testing; and (iii) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (3)(i)(A) Hold an earned doctoral degree in a chemical, biological, clinical or medical laboratory science or medical technology from an accredited institution; or (B) Hold an earned doctoral degree; and ( 1 ) Have at least 16 semester hours of doctoral level coursework in biology, chemistry, medical technology (MT), clinical laboratory science (CLS), or medical laboratory science (MLS); or ( 2 ) An approved thesis or research project in biology/chemistry/MT/CLS/MLS related to laboratory testing for the diagnosis, prevention, or treatment of any disease or impairment of, or the assessment of the health of, human beings; and (ii) Be certified and continue to be certified by a board approved by HHS; and (iii) Have at least 2 years of: (A) Laboratory training or experience, or both: and (B) Laboratory experience directing or supervising high complexity testing; and (iv) Have at least 20 CE credit hours in laboratory practice that cover the director responsibilities defined in § 493.1445; or (4) Notwithstanding any other provision of this section, an individual is considered qualified as a laboratory director of high complexity testing under this section if they were qualified and serving as a laboratory director of high complexity testing in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. (5) For the subspecialty of oral pathology, be certified by the American Board of Oral Pathology, American Board of Pathology, or the American Osteopathic Board of Pathology. [57 FR 7172, Feb. 28, 1992, as amended at 58 FR 5234, Jan. 19, 1993; 59 FR 62609, Dec. 6, 1994; 62 FR 25858, May 12, 1997; 63 FR 55034, Oct. 14, 1998; 65 FR 82944, Dec. 29, 2000; 68 FR 3713, Jan. 24, 2003; 88 FR 90041, Dec. 28, 2023]
Source: eCFR, Title 42, Part 493, current as of November 24, 2026.
Full text: 42 CFR § 493.1445 Standard; Laboratory director responsibilities
§ 493.1445 Standard; Laboratory director responsibilities. The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, record and report test results promptly, accurately and proficiently, and for assuring compliance with the applicable regulations. (a) The laboratory director, if qualified, may perform the duties of the technical supervisor, clinical consultant, general supervisor, and testing personnel, or delegate these responsibilities to personnel meeting the qualifications under §§ 493.1447, 493.1453, 493.1459, and 493.1487, respectively. (b) If the laboratory director reapportions performance of his or her responsibilities, he or she remains responsible for ensuring that all duties are properly performed. (c) The laboratory director must: (1) Be onsite at least once every 6 months, with at least 4 months between the minimum two on-site visits. Laboratory directors may elect to be on-site more frequently and must continue to be accessible to the laboratory to provide telephone or electronic consultation as needed; and (2) Provide documentation of these visits, including evidence of performing activities that are part of the laboratory director responsibilities. (d) Each individual may direct no more than five laboratories. (e) The laboratory director must— (1) Ensure that testing systems developed and used for each of the tests performed in the laboratory provide quality laboratory services for all aspects of test performance, which includes the preanalytic, analytic, and postanalytic phases of testing; (2) Ensure that the physical plant and environmental conditions of the laboratory are appropriate for the testing performed and provide a safe environment in which employees are protected from physical, chemical, and biological hazards; (3) Ensure that— (i) The test methodologies selected have the capability of providing the quality of results required for patient care; (ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; and (iii) Laboratory personnel are performing the test methods as required for accurate and reliable results; (4) Ensure that the laboratory is enrolled in an HHS-approved proficiency testing program for the testing performed and that— (i) The proficiency testing samples are tested as required under subpart H of this part; (ii) The results are returned within the timeframes established by the proficiency testing program; (iii) All proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require corrective action; and (iv) An approved corrective action plan is followed when any proficiency testing result is found to be unacceptable or unsatisfactory; (5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur; (6) Ensure the establishment and maintenance of acceptable levels of analytical performance for each test system; (7) Ensure that all necessary remedial actions are taken and documented whenever significant deviations from the laboratory's established performance characteristics are identified, and that patient test results are reported only when the system is functioning properly; (8) Ensure that reports of test results include pertinent information required for interpretation; (9) Ensure that consultation is available to the laboratory's clients on matters relating to the quality of the test results reported and their interpretation concerning specific patient conditions; (10) Ensure that a general supervisor provides on-site supervision of high complexity test performance by testing personnel qualified under § 493.1489(b)(5); (11) Employ a sufficient number of laboratory personnel with the appropriate education and either experience or training to provide appropriate consultation, properly supervise and accurately perform tests and report test results in accordance with the personnel responsibilities described in this subpart; (12) Ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results; (13) Ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills; (14) Ensure that an approved procedure manual is available to all personnel responsible for any aspect of the testing process; and (15) Specify, in writing, the responsibilities and duties of each consultant and each supervisor, as well as each person engaged in the performance of the preanalytic, analytic, and postanalytic phases of testing, that identifies which examinations and procedures each individual is authorized to perform, whether supervision is required for specimen processing, test performance or result reporting and whether supervisory or director review is required prior to reporting patient test results. [57 FR 7172, Feb. 28, 1992, as amended at 68 FR 3714, Jan. 24, 2003; 88 FR 90041, Dec. 28, 2023]
Source: eCFR, Title 42, Part 493, current as of November 24, 2026.